HP StorageWorks Fabric OS 6.1.1 administrator guide (5697-0235, December 2009)

Fabric OS 6.1.1 administrator guide 103
Sample mibCapability configuration
DCX:admin> snmpconfig --show mibcapability
FE-MIB:YES
SW-MIB: YES
FA-MIB: YES
FICON-MIB: YES
HA-MIB: YES
FCIP-MIB: YES
ISCSI-MIB: NO
SW-TRAP: YES
swFCPortScn: YES
swEventTrap: YES
swFabricWatchTrap: YES
swTrackChangesTrap: YES
FA-TRAP: YES
connUnitStatusChange: YES
connUnitEventTrap: YES
connUnitSensorStatusChange: YES
connUnitPortStatusChange: YES
SW-EXTTRAP: NO
FICON-TRAP: YES
linkRNIDDeviceRegistration: YES
linkRNIDDeviceDeRegistration: YES
linkLIRRlistenerAdded: YES
linkLIRRListenerRemoved: YES
linkRLIRFailureIncident: YES
HA-TRAP: YES
fruStatusChanged: YES
cpStatusChanged: YES
fruHistoryTrap: YES
FCIP-TRAP: NO
Sample systemGroup configuration (default)
switch:admin> snmpconfig --default systemGroup
*****
This command will reset the agent's system group configuration back to
factory default
*****
sysDescr = Fibre Channel Switch
sysLocation = End User Premise
sysContact = Field Support
authTraps = 0 (OFF)
*****
Are you sure? (yes, y, no, n): [no] y
Secure file copy
You can use the configure command to specify that secure file copy (SCP) is used for configuration
uploads and downloads.