HP StorageWorks Fabric OS 6.1.1 administrator guide (5697-0235, December 2009)

Fabric OS 6.1.1 administrator guide 25
The login prompt is displayed when the Telnet connection finds the switch in the network
5. Enter the account ID at the login prompt.
See ”Changing passwords” on page 25 for instructions on how to log in for the first time.
6. Enter the password.
If you have not changed the system passwords from the default, you are prompted to change them.
Enter the new system passwords, or press Ctrl-C to skip the password prompts. See ”Changing default
account passwords at login” on page 26.
7. Verify that the login was successful.
The prompt displays the switch name and user ID to which you are connected.
login: admin
password: xxxxxxx
Using a console session on the serial port
Note the following behaviors for serial connections:
Some procedures require that you connect through the serial port; for example, setting the IP address or
setting the boot PROM password.
If you are using a Fabric OS version prior to 6.x, and secure mode is enabled, connect through the
serial port of the primary FCS switch.
4/256 SAN Director and DC Director: You can connect to CP0 or CP1 using either of the two serial
ports.
To connect through the serial port:
1. Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the workstation.
If the serial port on the workstation is RJ-45 instead of RS-232, remove the adapter on the end of the
serial cable and insert the exposed RJ-45 connector into the RJ-45 serial port on the workstation.
2. Open a terminal emulator application (such as HyperTerminal on a PC, or TERM, TIP, or Kermit in a
UNIX environment), and configure the application as follows:
In a Windows environment:
In a UNIX environment, enter the following string at the prompt:
tip /dev/ttyb -9600
If ttyb is already in use, use ttya instead and enter the following string at the prompt:
tip /dev/ttya -9600
Changing passwords
The switch automatically prompts you to change the default account passwords after logging in for the first
time. If you do not change the passwords, the switch prompts you after each subsequent login until all the
default passwords have been changed.
Parameter Value
Bits per second 9600
Databits 8
Parity None
Stop bits 1
Flow control None