HP StorageWorks Fabric OS 6.1.1 administrator guide (5697-0235, December 2009)

Fabric OS 6.1.x administrator guide 287
The following example shows whether or not a port is configured for NPIV:
switch:admin> portcfgshow
Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent Disable.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
Use the switchShow and portShow commands to view NPIV information for a given port. If a port is an
F_Port, and you issue the switchShow command, the port WWN of the N_Port is returned. For an NPIV
F_Port, there are multiple N_Ports, each with a different port WWN. The switchShow command output
indicates whether a port is an NPIV F_Port, and identifies the number of virtual N_Ports behind it. The
following is sample output from the switchShow command:
switch: admin> switchshow
switchName:swd77
switchType:32.0
switchState: Online
switchMode:Native
switchRole:Principal
switchDomain: 99
switchId:fffc63
switchWwn:10:00:00:05:1e:35:37:40
zoning: OFF
switchBeacon:OFF
Area Port Media Speed State
==============================
0 0 id N2 Online F-Port 50:05:07:64:01:20:73:b8
1 1 id N2 Online F-Port 50:05:07:64:01:60:73:b8
2 2 id N2 Online F-Port 65 NPIV public
3 3 id N2 Online F-Port 50:05:07:64:01:e0:73:b8
4 4 id N2 Online F-Port 50:05:07:64:01:20:73:b5
...
<output truncated>