322 Using the FC-FC routing service
3. Issue the portEnable command to enable the ports that you disabled in step 2. You can now
physically attach ISLs from the Fibre Channel Router to the edge fabric.
switch:admin> portenable 7/10
4. Issue the portCfgShow command to view ports that are persistently disabled.
switch:admin> portcfgshow 7/10
Area Number: 74
Speed Level: AUTO
Trunk Port OFF
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
NPIV capability ON
EX Port ON
Mirror Port ON
FC Fastwrite ON
5. After identifying such ports, issue the portCfgPersistentEnable command to enable the port,
and then the portCfgShow command to verify the port is enabled.
switch:admin> portcfgpersistentenable 7/10
switch:admin> portcfgshow 7/10
Area Number: 74
Speed Level: AUTO
Trunk Port OFF
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
NPIV capability ON
EX Port ON
Mirror Port ON
FC Fastwrite ON