HP StorageWorks Fabric OS 6.1.1 administrator guide (5697-0235, December 2009)

354 Administering advanced performance monitoring
The Directors have a total of 10 slots. Slot numbers 5 and 6 are control processor blades; slots 1
through 4 and 7 through 10 are port blades. For 16-port blades, there are 16 ports, counted from
the bottom, numbered 0 to 15. For 32-port blades, there are 32 ports numbered 0 to 31.
portnumber specifies a port number. Valid values for port number vary, depending on the switch
type. This operand is required.
interval specifies an interval in seconds. The interval must be greater than or equal to five seconds.
For end-to-end monitoring, the Tx and Rx counts are measured in bytes. This operand is optional.
The following example displays an end-to-end monitor on a port at 6-second intervals:
switch:admin> perfMonitorShow --class EE 4/5 6
perfmonitorshow 53, 6: Tx/Rx are # of bytes and crc is # of crc errors
0 1 2 3 4
------------- ------------- ------------- ------------- -------------
crc Tx Rx crc Tx Rx crc Tx Rx crc Tx Rx crc Tx Rx
============= ============= ============= ============= =============
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 53m 4.9m 0 53m 4.9m 0 53m 4.9m 0 53m 4.9m 0 53m 0
0 53m 4.4m 0 53m 4.4m 0 53m 4.4m 0 53m 4.4m 0 53m 0
0 53m 4.8m 0 53m 4.8m 0 53m 4.8m 0 53m 4.8m 0 53m 0
0 53m 4.6m 0 53m 4.6m 0 53m 4.6m 0 53m 4.6m 0 53m 0
0 53m 5.0m 0 53m 5.0m 0 53m 5.0m 0 53m 5.0m 0 53m 0
0 53m 4.8m 0 53m 4.8m 0 53m 4.8m 0 53m 4.8m 0 53m 0
0 53m 4.5m 0 53m 4.5m 0 53m 4.5m 0 53m 4.5m 0 53m 0
0 52m 4.5m 0 52m 4.5m 0 52m 4.5m 0 52m 4.5m 0 52m 0
0 52m 5.0m 0 52m 5.0m 0 52m 5.0m 0 52m 5.0m 0 52m 0
0 52m 4.5m 0 52m 4.5m 0 52m 4.5m 0 52m 4.5m 0 52m 0
0 52m 4.6m 0 52m 4.6m 0 52m 4.6m 0 52m 4.6m 0 52m 0