408 Configuring and monitoring FCIP extension services
To verify that a VE_Port or VEX_Port is online, use the switchShow command to view and verify that the
FCIP tunnel is online.
Enabling persistently disabled ports
Before an FCIP tunnel can be used, the associated ports must be persistently enabled.
NOTE: VEX_Port Users: If the fabric is already connected, you must leave the ge0 and ge1 ports disabled
until after you have configured the VEX_Port; this prevents unintentional merging of the two fabrics.
To enable a persistently disabled port:
1. Connect to the switch and log in using an account assigned to the admin role.
2. Issue the portCfgShow command to view ports that are persistently disabled.
3. After identifying the ports, issue the portCfgPersistentEnable command to enable the ports.
4. Issue the portCfgShow command to verify the port is persistently enabled:
switch:admin06> portcfgpersistentenable 8/16
switch:admin06> portcfgpersistentenable 8/17
switch:admin06> portenable 8/18
switch:admin06> portenable 8/19
switch:admin06> switchshow
switchName:switch
switchType:42.2
switchState:Online
switchMode:Native
switchRole:Subordinate
switchDomain:4
switchId:fffc04
switchWwn:10:00:00:60:69:80:0d:bc
zoning:ON (LSAN001)
switchBeacon:OFF
blade3 Beacon: OFF
blade4 Beacon: OFF
blade8 Beacon: OFF
FC router:ON
FC router BB Fabric ID:1
Area Slot Port Media Speed State
=====================================
32 3 0 id N4 Online F-Port 50:03:0d:30:0d:13:00:09
33 3 1 id N4 Online F-Port 50:03:0d:30:0d:13:00:11
34 3 2 id N4 Online F-Port 50:03:0d:30:0d:13:00:13
35 3 3 id N4 Online F-Port 50:03:0d:30:0d:13:00:15
36 3 4 id N2 Online F-Port 21:00:00:e0:8b:08:bd:20
<output truncated>
210 8 18 -- -- Online VE-Port 50:00:51:e3:51:55:3f:1e
"fcr_xd_3_16" (downstream)
211 8 19 -- -- Online VE-Port 50:00:51:e3:70:42:5f:76
"fcr_xd_5_17" (downstream)
<output truncated>
223 8 31 -- -- Offline
8 ge0 id 1G Online