Brocade Fabric OS MIB Reference Guide v6.1.0 (53-1000602-02, June 2008)

534 Fabric OS MIB Reference
53-1000602-02
swAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.1.8
5
swAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.1.8
The desired administrative status of the switch. A management station might place the switch in a
desired state by setting this object accordingly.
Values Possible values are:
online (1) Set the switch to be accessible by an external FC port.
offline (2) Set the switch to be inaccessible.
testing (3) Set the switch to run the built-in test.
faulty (4) Set the switch to a “soft” faulty condition.
reboot (5) Set the chassis to reboot in 1 second.
fastboot (6) Set the chassis to fastboot in 1 second. Fastboot causes the chassis to boot but
omit the POST.
switchReboot (7) Set the current switch to reboot in 1 second.
When the switch is in faulty state, only two states can be set: faulty and
reboot/fastboot/switchReboot.
For the Brocade 3250, 3850, 3900, 24000, 48000 and DCX director the testing (3), faulty (4)
values are not applicable.
The switchReboot (7) value only applies to the Brocade 12000, 24000, and 48000 directors.
The Possibles values for Brocade 300, 5100 and 5300 are either online(1) and offline(2).