swFCPortPhyState 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3
5
swFCPortPhyState 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3
The physical state of the port.
Values Possible values are:
• noCard (1) No card is present in this switch slot.
• noTransceiver (2) No Transceiver module in this port (Transceiver is the generic name for GBIC,
SFP, and so on).
• laserFault (3) The module is signaling a laser fault (defective GBIC).
• noLight (4) The module is not receiving light.
• noSync (5) The module is receiving light but is out of sync.
• inSync (6) The module is receiving light and is in sync.
• portFault (7) The port is marked faulty (defective GBIC, cable, or device).
• diagFault (8) The port failed diagnostics (defective G_Port or FL_Port card or motherboard).
• lockRef (9) Port is locking to the reference signal.