Brocade Access Gateway Administrator's Guide Supporting Fabric OS v7.0.0 (53-1002156-01, April 2011)

56 Access Gateway Administrator’s Guide
53-1002156-01
Trunking in Access Gateway mode
3
5. Enter the switchhow command to display the switch or port information, including created
trunks.
Disabling F_Port trunking
Use the following steps to disable F_Port trunking.
1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the porttrunkarea --disable
command.
switch:admin> porttrunkarea --disable 36-39
ERROR: port 36 has to be disabled
If an error occurs as in the previous example, disable each port using the portdisable port
command, and then reissue the command.
switch:admin> porttrunkarea --disable 36-39
trunk area 37 disabled for ports 36, 37, 38 and 39.
Monitoring trunking
For F_Port masterless trunking, you must install Filter, EE, or TT monitors on the F_Port trunk port.
Whenever the master port changes, it is required to move the monitor to the new master port. For
example, if a master port goes down, a new master is selected from the remaining slave ports. The
Advanced Performance Monitor (APM) must delete the monitor from the old master and install the
monitor on the new master port. If you attempt to add a monitor to a slave port, it is automatically
added to the master port.
Trunking considerations for the Edge switch
Table 8 describes the Access Gateway trunking considerations for the Edge switch.
TABLE 8 Access Gateway trunking considerations for the Edge switch
Category Description
Area assignment You statically assign the area within the trunk group on the Edge
switch. That group is the F_Port masterless trunk.
The static trunk area you assign must fall within the F_Port trunk
group starting from port 0 on an Edge switch or blade.
The static trunk area you assign must be one of the port’s default
areas of the trunk group.
Authentication Authentication occurs only on the F_Port trunk master port and
only once per the entire trunk. This behavior is the same as
E_Port trunk master authentication. Because only one port in the
trunk does FLOGI to the switch, and authentication follows FLOGI
on that port, only that port displays the authentication details
when you issue the portshow command.
Note: Switches in Access Gateway mode do not perform