Brocade Fabric Watch Administrator's Guide v6.1.0 (53-1000601-02, June 2008)

52 Fabric Watch Administrator’s Guide
53-1000601-02
Fabric Watch using SNMP configuration
3
Fan Alarm Action: (0..17) [0]
WWN Alarm State: (0..31) [0]
WWN Alarm Action: (0..17) [0]
Fru configuration left unchanged
Specifying triggers for alarms
You can specify triggers for any number of alarm states or alarm actions. The first prompt enables
you to select which FRU states trigger events.
1. Add the numbers beside each state (for the states you want to include).
2. Enter the total at the prompt.
For example, to trigger events using the Absent, Off, and Faulty states, add the assigned values and
enter that value at the prompt. In this case, the values are 1, 8, and 16, respectively, and the total
is 25.
Fabric Watch using SNMP configuration
NOTE
The instructions given in this procedure apply to the AdventNet MIB browser. The procedure might
vary if you use other MIB browsers.
Configuring Fabric Watch using SNMP
1. Open a MIB browser, such as the one shown below.
2. Load the appropriate MIB files. First, load the Brocade common MIB file (BRCD_v5_0.mib),
followed by the Brocade software MIB file (SW_v5_3.mib). If this is successful, the system
displays a screen similar to
Figure 9.
FIGURE 9 Configuring Fabric Watch using SNMP