70 Fabric Watch Administrator’s Guide
53-1000601-02
Port class
DRAFT: BROCADE CONFIDENTIAL
F/FL_Port class
Table 24 provides default settings for areas in the F/FL_Port class.
Port fencing can only be enabled or disabled for the following areas for the F/FL_Port class:
Link Failure Count
Loss of Synchronization Count
Primitive Sequence Protocol Error
Invalid Transmission Word
Invalid CRC Count
State Changes Monitors state
changes
Unit: Changes
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit
Performance
Monitors the
transmit rate, by
percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Utilization (VE_port) Monitors utilization
of VE-ports by
percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Packet Loss
(VE_port)
Monitors total packet
loss by percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
TABLE 23 E_Port class (Continued)
Area Description Default threshold settings Default alarm settings Threshold state