Brocade Troubleshooting and Diagnostics Guide v6.1.0 (53-1000853-01, June 2008)

Fabric OS Troubleshooting and Diagnostics Guide 19
53-1000853-01
Link issues
3
Link issues
Symptom LEDs are flashing.
Probable cause and recommended action
Depending on the rate of the flash and the color of the LED this could mean several things. To
determine what is happening on either your port status LED or power status LED, refer to that
switch’s model hardware reference manual. There is a table that describes the LEDs purpose and
explains the current behavior as well as provides suggested resolutions.
Symptom LEDs are steady.
Probable cause and recommended action
The color of the LED is important in this instance. To determine what is happening on either your
port status LED or power status LED, refer to that switch’s model hardware reference manual.
There is a table that describes the LEDs purpose and explains the current behavior as well as
provides suggested resolutions.
Symptom No light from the LEDs.
Probable cause and recommended action
If there is no light coming from the LED, then no signal is being detected. Check your cable and SFP
to determine the physical fault.
Symptom EX_Port does not form.
Probable cause and recommended action
This usually happens when the fabric parameters are set up correctly for the EX_Port.
A common parameter to check is the use of the World Wide Node Name (WWNN) instead of the
port World Wide Name (pWWN). To fix this problem use the pWWN instead.
Connection problems
If a host is unable to detect its target, for example, a storage or tape device, you should begin
troubleshooting the problem at the switch. Determine if the problem is the target or the host, then
continue to divide the suspected problem-path in half until you can pinpoint the problem. One of
the most common solutions is zoning. Verify that the host and target are in the same zone. For
more information on zoning, refer to Chapter 8, “Zone Issues”.
Checking the logical connection
1. Enter the switchShow command.
2. Review the output from the command and determine if the device successfully logged into the
switch.
A device that is logically connected to the switch is registered as an F_, L_, E_, EX_, VE_,
VEX_, or N_Port.