switch:admin> porterrshow
frames enc crc too too bad enc disc link loss loss frjt fbsy
tx rx in err shrt long eof out c3 fail sync sig
=====================================================================
0: 39m 95m 0 0 0 0 0 364k 10 13 6.1k 8 0 0
1: 2.6g 4.1g 0 0 0 0 0 150k 46 0 0 1 0 0
2: 3.7g 2.0g 0 0 0 0 0 18 134 0 0 0 0 0
3: 2.2g 2.9g 0 0 0 0 0 19 127 0 0 0 0 0
4: 20m 19m 0 0 0 0 0 241k 10 10 4.3k 5 0 0
5: 113m 2.4g 0 0 0 0 0 96k 12 0 0 1 0 0
6: 331m 359m 0 0 0 0 0 249m 1.4k 1 2.3k 2 0 0
7: 156m 171m 0 0 0 0 0 10m 1.4k 27 52 6 0 0
8: 3.0g 1.1g 5 2 0 0 0 117k 1 38 62 28 0 0
9: 2.0g 807m 0 0 0 0 0 12k 0 10 19 2 0 0
10: 0 0 0 0 0 0 0 139k 0 0 0 1 0 0
11: 0 0 0 0 0 0 0 129k 0 0 0 1 0 0
12: 1.7g 3.1g 0 0 0 0 0 426 1.4k 0 0 0 0 0
13: 697m 691m 0 0 0 0 0 6.0k 1.4k 0 0 0 0 0
14: 2.3g 1.7g 0 0 0 0 0 107 1.0k 0 0 0 0 0
15: 3.1g 893m 0 0 0 0 0 58 37k 0 0 0 0 0
NOTE
When two shared ports on an FC4-48 blade are receiving traffic and the primary port goes offline,
all the frames that are out for delivery for the primary port are dropped, but the counters show them
as dropped on the secondary port that shares the same area. Error counters increment
unexpectedly for the secondary port, but the secondary port is operating properly.
If this occurs, clear the counters using the portStatsClear command on the secondary port after
primary port goes offline.
5. Enter the portFlagsShow command; then, check to see how a port has logged in and where a
login failed (if a failure occurred):
switch:admin> portflagsshow
Port SNMP Physical Flags
-------------------------------
0 Offline In_Sync PRESENT U_PORT LED
1 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT
2 Offline No_Light PRESENT U_PORT LED
3 Offline No_Module PRESENT U_PORT LED
4 Offline No_Module PRESENT U_PORT LED
5 Offline No_Light PRESENT U_PORT LED
6 Offline No_Module PRESENT U_PORT LED
7 Offline No_Module PRESENT U_PORT LED
8 Offline No_Light PRESENT U_PORT LED
9 Offline No_Light PRESENT U_PORT LED
10 Offline No_Module PRESENT U_PORT LED
11 Offline No_Module PRESENT U_PORT LED
12 Offline No_Module PRESENT U_PORT LED
13 Offline No_Module PRESENT U_PORT LED
14 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP LED ACCEPT
15 Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT SEGMENTED LOGIN
LED