Brocade Troubleshooting and Diagnostics Guide v6.1.0 (53-1000853-01, June 2008)

Fabric OS Troubleshooting and Diagnostics Guide 29
53-1000853-01
Media-related issues
3
6. Enter the portLogDumpPort portid command where the port ID is the port number; then, view
the device-to-switch communication.
switch:admin> portlogdump 13
time task event port cmd args
-------------------------------------------------
Tue Apr 24 19:45:58 2007
19:45:58.728 PORT Tx3 0 12 22000000,00000000,ffffffff,11010000
19:45:58.778 SPEE sn 0 WS 000000f0,00000000,00000000
19:45:58.787 SPEE sn 0 WS 00000001,00000000,00000000
19:45:59.327 SPEE sn 0 NC 00000002,00000000,00000001
19:45:59.328 LOOP loopscn 0 LIP 8002
19:45:59.328 LOOP loopscn 0 LIP f7f7
19:45:59.328 PORT Tx3 0 12 22000000,00000000,ffffffff,11010000
19:45:59.378 SPEE sn 0 WS 000000f0,00000000,00000000
19:45:59.387 SPEE sn 0 WS 00000001,00000000,00000000
19:45:59.927 SPEE sn 0 NC 00000002,00000000,00000001
19:45:59.927 LOOP loopscn 0 LIP 8002
19:45:59.928 LOOP loopscn 0 LIP f7f7
19:45:59.928 PORT Tx3 0 12 22000000,00000000,ffffffff,11010000
NOTE
See “Port log” on page 101 for overview information about portLogDump.
Media-related issues
This section provides procedures that help pinpoint any media-related issues, such as bad cables
and SFPs, in the fabric. The tests listed in Table 6 are a combination of structural and functional
tests that can be used to provide an overview of the hardware components and help identify
media-related issues.
Structural tests perform basic testing of the switch circuit. If a structural test fails, replace the
main board or port blade.
Functional tests verify the intended operational behavior of the switch by running frames
through ports or bypass circuitry.
The following procedures are for checking switch-specific components.
TABLE 6 Component test descriptions
Test name Operands Checks
portTest [-ports itemlist] [-iteration count]
[-userdelay time] [-timeout time]
[-pattern pattern] [-patsize size]
[-seed seed] [-listtype porttype]
Used to isolate problems to a single
replaceable element and isolate
problems to near-end terminal
equipment, far-end terminal
equipment, or transmission line.
Diagnostics can be executed every day
or on demand.
spinFab [-nmegs count] [-ports itemlist] [-setfail mode] Tests switch-to-switch ISL cabling and
trunk group operations.