Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
308 Fabric OS Command Reference
53-1000599-02
iscsiPortCfg
2
iscsiPortCfg
Displays or modifies iSCSI port parameters.
Synopsis iscsiportcfg --clearstats slot/geport
iscsiportcfg --default slot/geport
iscsiportcfg --show slot/geport [-v]
iscsiportcfg --modify slot/geport options
Description Use this command to display or modify the iSCSI port parameters.
The default iSCSI port settings are as follows:
TABLE 16 Default iSCSI port settings
Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands This command has the following operands:
--modify Modifies the port parameters on the specified port. Valid options are:
-e value Specifies the error recovery level; values are 0, 1, or 2.
-c value Specifies the TCP of connections; values are 1 or 2.
-d value Enables or disables data digest support; specify 0 to disable or 1 to enable.
-a value Enables or disables header digest support; specify 0 to disable or 1 to
enable.
-i value Enables or disables immediate data support; specify 0 to disable or 1 to
enable.
-f value Specifies the first burst length value; values include 512, 1024, 2048, 4096,
8192, 16384, and 32768.
--clearstats Clears port-level iSCSI statistics on the specified port.
--default Resets the port to the default values. See the "Description" section for the list
of default values.
Setting Default
Error recovery level 0
Connections per session 1
Connections per session Disabled
Header digest support Disabled
Immediate data support No
First burst length value 512