Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 391
53-1000599-02
perfAddReadMonitor
2
perfAddReadMonitor
Adds a filter-based performance monitor for the SCSI Read command.
Synopsis perfaddreadmonitor [slotnumber/]portnumber [alias]
Description Use this command to create a filter-based monitor that counts the number of SCSI FCP Read
commands in Fibre Channel frames. Only frames transmitted are counted.
Execution of this command displays a numeric key that uniquely identifies the monitor. Use the
perfMonitorShow command for a listing of valid keys and user-defined aliases.
Notes This command requires an Advanced Performance Monitoring license.
This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and
GbE ports.
The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands This command has the following operands:
slotnumber For bladed systems only, this operand specifies the slot number of the port
on which the monitor is to be added, followed by a slash (/).
portnumber Specifies the number of the port on which the monitor is to be added, relative
to its slot for bladed systems. Use switchShow for a list of valid ports.
alias Specifies a name for this monitor. Strings exceeding 10 characters are
truncated. To accommodate spaces, the string must be surrounded by
quotation marks. Spaces count toward the character limit but are removed.
This operand is optional. The default alias is “SCSI Read”.
Examples To add an SCSI read monitor to a port:
switch:admin> perfaddreadmonitor 2/4 SCSI_R
SCSI Read filter monitor #2 added
See Also perfAddEEMonitor, perfAddIPMonitor, perfAddRWMonitor, perfAddSCSIMonitor,
perfAddUserMonitor, perfAddWriteMonitor