Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 415
53-1000599-02
perfTTmon
2
Operands This command has the following operands:
slotnumber For bladed systems only, specifies the slot number of the port on which to
install Top Talkers, followed by a slash (/).
portnumber Specifies the number of the port on which the Top Talker is to be installed,
relative to its slot for bladed systems. Use switchShow for a list of valid ports.
F_Port Top Talker commands:
--add Installs the Top Talker monitor on a specified F_Port.
egress | ingress
Used with the --add option to specify the direction in which the traffic is
monitored as incoming or outgoing. This operand is required.
--show Displays the top talking flows on a specified port.
number of top talking flows
Specifies "n" top talking flows. Valid values are between 1 and 32. If a value
greater than 32 is entered, Top Talker displays counters for only 32 flows and
a warning message. This operand is optional; if omitted, the command
displays the top 8 flows.
wwn | pid Specifies the output display as either WWN or PID format. This operand is
optional. If omitted, the command displays in WWN format.
--delete Deletes an existing Top Talker monitor on a specified F_Port.
Fabric Mode Top Talker commands:
--add fabricmode Installs the Top Talker monitor on all switches in the fabric.When a new switch
joins the fabric, this command needs to be run again on the switch. The TT
config information is not propagated automatically to the new switch.
--show Displays top talking flows on the switch, for a given domain ID.
dom dom_id Specifies the domain ID for the flow display.
number of top talking flows
Specifies "n" top talking flows. Valid values are between 1 and 32. If a value
greater than 32 is entered, Top Talker displays counters for only 32 flows and
a warning message.This operand is optional; if omitted, the command
displays the top 8 flows.
wwn | pid Specifies display as either WWN or PID format. This operand is optional. If
omitted, the command displays in WWN format.
--delete fabricmode
Deletes the Fabric Mode Top Talker.
Examples To add an F_Port Top Talker to blade 1 port 2 (which should be an F_Port):
Switch:admin> perfttmon --add ingress 1/2