Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 465
53-1000599-02
portCfgShow
2
VC Link Init Displays (..) or OFF when the long distance link initialization option is turned
off. Displays ON when it is turned on for long distance mode. This value is set
by the portCfgLongDistance command.
Locked L_Port Displays ON when the port is locked to L_Port only. Displays (..) or OFF when
L_Port lock mode is disabled and the port behaves as a U_Port). This value is
set by the portCfgLPort command.
Locked G_Port Displays ON when the port is locked to G_Port only. Displays (..) or OFF when
G_Port lock mode is disabled and the port behaves as a U_Port. This value is
set by the portCfgGPort command.
Disabled E_Port Displays ON when the port is not allowed to be an E_Port. Displays (..) or OFF
when the port is allowed to function as an E_Port. This value is set by the
portCfgEPort command.
ISL R_RDY Mode Displays ON when ISL R_RDY mode is enabled on the port. Displays (..) or OFF
when ISL R_RDY mode is disabled. This value is set by the portCfgISLMode
command.
RSCN Suppression
Displays ON when RSCN suppression is enabled on the port. Displays (..) or
OFF when RSCN suppression is disabled. This value is set by the portCfg
rscnsupr command.
Persistent Disable Displays ON when the port is persistently disabled; otherwise displays (..) or
OFF. This value is set by the portCfgPersistentDisable command.
NPIV capability Displays ON when N_Port ID Virtualization (NPIV) is enabled on the port
(default). Displays (..) or OFF when NPIV capability is disabled. This value is
set by the portCfgNPIVPort command.
QOS E_Port Displays ON when Quality of Service (QoS) is enabled on the port. Displays (..)
or OFF when QoS is disabled. By default, QoS is enabled by best effort based
on availability of buffers. This value is set by the portCfgQos command.
EX_port. Displays ON when the port is configured as an EX_Port. Otherwise displays (..)
or OFF. This value is set by the portCfgExPort command.
Mirror Port Displays ON when Mirror Port is enabled on the port. Displays (..) or OFF when
Mirror Port is disabled. This value is set by the portCfg mirrorport command.
FC Fastwrite Displays ON when FC Fastwrite is enabled on the port or (..) or OFF when
disabled. Fastwrite is disabled by default. This value is set by the portCfg
fastwrite command.
Rate Limit Displays ON when ingress rate limit is set on the port or (..) or OFF when the
ingress rate limiting feature is disabled. This value is set by the portCfgQos
--setratelimit command. The default value is OFF.
Credit Recovery Displays ON when Credit Recovery is enabled on the port or (..) or OFF when
disabled. This value is set by the portCfgCreditRecovery command. The credit
recovery feature is enabled by default, but only ports configured as long
distance ports can utilize this feature.