Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
546 Fabric OS Command Reference
53-1000599-02
portTrunkArea
2
32 32 id N4 No_Light
33 33 id N4 No_Light
34 34 id N4 No_Light
35 35 id N4 No_Light
36 36 id N4 Online F-Port 20:14:00:05:1e:41:4b:4d
37 37 id N4 Online F-Port 20:15:00:05:1e:41:4b:4d
38 38 id N4 Online F-Port 20:16:00:05:1e:41:4b:4d
39 39 id N4 Online F-Port 2 NPIV public
5. Display TA enabled port configuration:
switch:admin> porttrunkarea --show enabled
Port Type State Master TA DA
-------------------------------------
36 -- -- -- 37 36
37 -- -- -- 37 37
38 -- -- -- 37 38
39 -- -- -- 37 39
To disable masterless F_Port trunking on ports 36-39:
switch:admin> porttrunkarea --disable 36-39
ERROR: port 36 has to be disabled
Disable each port prior to removing ports from the TA. Then reissue the command:
switch:admin> porttrunkarea --disable 36-39
Trunk area 37 disabled for ports 36, 37, 38 and 39.
To display trunk details for a user assigned TA 38 that includes ports 36-39:
switch:admin> porttrunkarea --show trunk
Trunk Area 38: 39->23 sp: 4.000G bw: 16.000G deskew 16 MASTER
38->22 sp: 4.000G bw: 4.000G deskew 15
37->21 sp: 4.000G bw: 4.000G deskew 16
36->20 sp: 4.000G bw: 4.000G deskew 16
To configure a TA on an enterprise-class platform including ports 13 and 14 on slot 10 with port
index of 125:
1. Disable the ports to be included in the TA.
2. Enable TA for ports 13 and 14 on slot 10 with port index of 125:
switch:admin> porttrunkarea --enable 10/13-14 -index 125
Trunk index 125 enabled for ports 10/13 and 10/14.
3. Show the TA port configuration (ports still disabled):
switch:admin> porttrunkarea --show enabled
Slot Port Type State Master TI DI
-------------------------------------------
10 13 -- -- -- 125 125
10 14 -- -- -- 125 126
-------------------------------------------