Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 601
53-1000599-02
slotPowerOff
2
slotPowerOff
Removes power from a slot.
Synopsis slotpoweroff slotnumber
Description Use this command to turn off the power to a blade unit. The slot must have a valid blade unit
present and the blade unit must be of a type that can be powered off.
Notes The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands This command has the following operand:
slotnumber Specify the slot number of the blade to be powered down. This operand is
required.
Examples To power off blade unit 3:
switch:admin> slotpoweroff 3
Slot 3 is being powered off
See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow