Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
604 Fabric OS Command Reference
53-1000599-02
slotShow
2
DIAG RUNNING POST1
The blade is present, powered on, and running the POST (power-on self-test).
DIAG RUNNING POST2
The blade is present, powered on, and running the pre-boot power on self
tests.
INITIALIZING The blade is present, powered on, and initializing hardware components.
ENABLED The blade is on and fully enabled.
ENABLED (User Ports Disabled)
The blade is on but the external ports have been disabled with the
bladeDisable command.
ENABLED (SAS Virtualization Disabled)
The blade is on, but due to an incompatibility between the FOS image and the
SAS or Application image, the SAS Virtualizaion services are disabled. Only
applies to the FA4-18 blade.
DISABLED The blade is powered on but disabled.
FAULTY The blade is faulty because an error was detected.
UNKNOWN The blade is inserted but its state cannot be determined.
Operands This command supports the following operands:
-p In addition to the basic slot status view, displays the following information
about power consumption:
Direct current (DC) power consumption for each Blade in Watts.
Total alternate current (AC) Power Consumption in Watts.
AC efficiency, as a percentage of total and BTU.
Power efficiency in Watts/port and Watts/Gb.
-m In addition to the basic slot status view, displays the Brocade model name for
each blade.
Examples To display a basic view of all slots and their status:
switch:user> slotshow
Slot Blade Type ID Status
-----------------------------------
1 SW BLADE 51 FAULTY
2 SW BLADE 51 DISABLED
3 SW BLADE 55 ENABLED(User Ports Disabled)
4 SW BLADE 51 DIAG RUNNING POST2
5 CORE BLADE 52 ENABLED
6 CP BLADE 50 ENABLED
7 CP BLADE 50 ENABLED
8 CORE BLADE 52 ENABLED
9 UNKNOWN VACANT
10 AP BLADE 33 LOADING
11 SW BLADE 55 DIAG RUNNING POST1
12 SW BLADE 51 INSERTED, NOT POWERED ON 1