Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000599-02, June 2008)

Table Of Contents
Fabric OS Command Reference 663
53-1000599-02
systemVerification
2
Diagnostics Each diagnostic test in this suit reports its own set of error messages when detecting a failure.
Refer to the Diagnostics section of individual diagnostic test help pages. These messages are
available only in the log file.
Refer to the Fabric OS Message Reference for more information.
Examples To initiate a system verification test on all switches in the fabric:
switch:admin> systemverification -short
systemverification: Setting parameters for short run.
systemverification: burnin parameters.
CURRENT - KEYWORD : DEFAULT
1 - number_of_runs : 1
2 - vib : 2
10 - thermal : 10
SYSTEMVERIFICATION - label : BURNIN
2 - min_lb_mode : 2
1 - tbr_passes : 1
1 - prt_on : 1
1 - cntmem_on : 1
1 - cmi_on : 1
1 - retention_on : 1
1 - cam_on : 1
1 - flt_passes : 50
1 - sta_passes : 25
1 - plb_nframes : 100
1 - txd_nframes : 50
1 - xpt_nframes : 200
1 - bpt_nframes : 20
1 - slk_nmegs : 50
1 - bpt_all_nframes : 30
1 - slk_all_nmegs : 50
systemverification: Arming the burnin run on switch 0.
systemverification: Starting burnin on Switch 0
systemverification: Monitoring progress of the burnin activity.
systemverification: Outputting Status
State Status Run Cmd TotCmds Script
COMPLETED PASS 1 22 22 switchburnin.sh
See Also burninErrShow, burninStatus, diagSetBurnin, diagSetCycle