topologyShow
2
Total Bandwidth The maximum bandwidth of the out port. A bandwidth that is less than 0.512
Gbps is adjusted to the nearest power of 2 value. A bandwidth in the range of
0.512 Gbps Included) to 1 Gbps (not included) is adjusted to the 0.512 Gbps
value. No adjustment takes place if the bandwidth is greater or equal to 1
Gbps.
Bandwidth Demand
The maximum bandwidth demand by the in ports.
Flags Always D, indicating a dynamic path. A dynamic path is discovered
automatically by the FSPF path selection protocol.
Operands The following operand is optional:
domain Specify the destination domain for which to display the topology information.
Examples To display the topology on a single switch: domain is local, details are not displayed.
switch:user> topologyshow
1 domains in the fabric; Local Domain ID: 97
When executed from an edge fabric, topologyshow displays details for all domains, including local
domains and local translate domains:
switch:user> topologyshow
6 domains in the fabric; Local Domain ID: 7
Domain: 1
Metric: 10500
Name: fcr_xd_1_1
Path Count: 1
Hops: 2
Out Port: 11
In Ports: 0 1 2 3 4 5 6 7 8 9 15
Total Bandwidth: 8.000 Gbps
Bandwidth Demand: 1275 %
Flags: D
Domain: 2
Metric: 1000
Name: fcr_fd_2
Path Count: 1
Hops: 2
Out Port: 15
In Ports: 0 1 2 3 4 5 6 7 8 9 11
Total Bandwidth: 2.000 Gbps
Bandwidth Demand: 4000 %
Flags: D
Domain: 3
Metric: 10500
Name: fcr_xd_3_5
Path Count: 1