burninErrClear
2
burninErrClear
Clears errors stored in nonvolatile memory during burn-in.
Synopsis burninerrclear slotnumber
Description Use this command to clear errors that were stored during burn-in in the nonvolatile memory of a
specified slot.
It is advisable to run the burninErrClear command prior to running diagSetBurnin and diagSetCycle
.
Note The execution of this command is subject to Admin Domain restrictions that may be in place. Refer
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability"
for details.
Operands The following operand is required:
slotnumber Specify a nonzero value for the slot number from which to clear burn-in errors.
Examples To clear burn-in errors from slot 2:
switch:admin> burninerrclear 2
See Also burninErrShow