Brocade Fabric Watch Administrator's Guide v6.2.0 (53-1001188-01, April 2009)

64 Fabric Watch Administrator’s Guide
53-1001188-01
Threshold configuration
8
12. Change the Threshold boundary level to custom by typing 3, and then select custom by
typing 2 at the Enter boundary level type.
1: change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change below alarm
4 : change custom unit 14 : change above alarm
5 : change custom time base 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 3
1 : Default
2 : custom
Enter boundary level type => : (1..2) [1] 2
13. Select apply threshold boundary changes by typing 9 at the Select choice prompt.
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change below alarm
4 : change custom unit 14 : change above alarm
5 : change custom time base 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 9
14. Type Enter until you reach the switch command prompt.