Setting up LSAN zone binding
1. Log in to the FC router as admin.
2. Enter the following command to add a pair of FC routers that can access each other:
FCR:Admin > fcrlsanmatrix --add -fcr wwn1 wwn2
where wwn1 and wwn2 are the WWNs of the FC routers.
3. Enter the following command to add a pair of edge fabrics that can access each other:
FCR:Admin > fcrlsanmatrix --add -lsan fid1 fid2
where fid1 and fid2 are the FIDs of the edge fabrics.
4. Enter the following command to apply the changes persistently:
FCR:Admin > fcrlsanmatrix --apply -all
Viewing the LSAN zone binding matrixes
1. Log on to the FC router as admin.
2. Enter the following command to view the FC router matrix:
FCR:Admin > fcrlsanmatrix --fabricview -fcr
Example:
FCR:Admin > fcrlsanmatrix --fabricview -fcr
SAVED FCR PAIRS
======================================================
FCR FCR
------------------------------------------------------
10:00:00:60:69:c3:12:b2 (2)10:00:00:60:69:c3:12:b3 (unknown)
3. Enter the following command to view the LSAN fabric matrix:
FCR:Admin > fcrlsanmatrix --fabricview -lsan
Example:
FCR:Admin > fcrlsanmatrix --fabricview -lsan
LSAN MATRIX is activated
Fabric ID 1 Fabric ID 2
--------------------------------------
4 5
4 7
10 19
Default LSAN Matrix:
1 2 8
Proxy PID configuration
When an FC router is first configured, the PIDs for the proxy devices are automatically assigned. Proxy PIDs
(as well as phantom domain IDs) persist across reboots.
The most common situation in which you would set a proxy PID is when you replace a switch. If you
replace the switch and want to continue using the old PID assignments, you can configure it to do so; this
value remains in the system even if the blade is replaced. To minimize disruption to the edge fabrics, set
the proxy PIDs to the same values used with the old hardware.
The fcrProxyConfig command is displayed or sets the persistent configuration of proxy devices. Used
with the -s slot option, it can also influence the assignment of the xlate domain port number (which is