3.6.0 Matrix Server Installation Guide (5697-7079, February 2008)

Chapter 3: Install PolyServe Matrix Server 20
Copyright © 1999-2008 PolyServe, Inc. All rights reserved.
Engenio Storage Arrays
To take hardware snapshots on Engenio storage arrays, the latest version
of SANtricity Storage Manager client software must be installed on all
servers in the cluster. Also, the latest version of firmware must be
installed on your storage array controllers. To obtain this software and
firmware, contact your Engenio representative.
HP EVA Storage Arrays
To take hardware snapshots or snapclones on Hewlett-Packard
StorageWorks Enterprise Virtual Array (EVA) storage arrays, a supported
version of the HP StorageWorks Scripting System Utility (SSSU) must be
installed on all servers in the cluster. Also, a supported version of
CommandView EVA software must be installed on your Management
Appliance. Be sure that your versions of SSSU and CommandView EVA
are consistent. The SSSU utility must be renamed to %Program
Files%\Hewlett-Packard\SANworks \Element Manager for
StorageWorks HSV\Bridge\sssu.exe. To obtain this software, contact
your Hewlett-Packard representative.
If Microsoft Windows SP2 is not installed on your servers, you will also
need to install Microsoft Knowledge Base Hotfix 899415. The hotfix is
available at:
http://support.microsoft.com/default.aspx?scid=kb;en-us;899415
16. Configure the Matrix
Configuration Information
The matrix is configured from the PolyServe Management Console. You
will be asked for the following information:
The IP address or hostname of each server that will be in the matrix.
The location of your Matrix Server license file.
A secret network key that provides security for network
communications among the matrix servers.
The fencing method that you want to use (either FibreChannel switch-
based fencing or Web Management-based fencing via server reset/
shutdown).