HP StorageWorks Storage System Scripting Utility reference (September 2005)

All
Te sts all disks in a selecte d array.
List of fully qualied disk names to exercise, comma separated and enclosed in quotes.
Tests specicdisksasspecied in the command.
STOP
Stops the testing.
SUMMAR Y
Provides a sum m ary report of the testing. This can be used to show status while testing is in progress and
also when testing is complete.
The followi ng is a sample output:
ss1> exer start "\Disk Groups\Ungrouped Disks\Disk 002"
ss1> exer sum
DILX Summary Report for Storage Cell ss1
----------------------------------------------------------
DILX process status: DILX Testing In Progress
Number of devices tested: 1
Disk 002
___________
Device handle:
noid: 0x808
id_type: 0x7
id_len: 0x10
id_value[0]: 0x20000004
id_value[1]: 0xcf792125
id_value[2]: 0
id_value[3]: 0
Device status: Testing in progress.
Total blocks transferred: 12098
Total reads issued: 329
Total writes issued: 77
1st bad sense key: 0
2nd bad sense key: 0
1st error flag: 0
2nd error flag: 0
Soft error count: 0
Hard error count: 0
1st bad ASC: 0
2nd bad ASC: 0
1st bad ASQ: 0
48
Utility command reference