HP StorageWorks Command View XP Command Line Interface (CLI) reference guide (B9357-96161, January 2006)
Command View XP Command Line Interface (CLI) reference guide 17
Differences between the disk array family commands
Ranges
Range arguments for the XP48/XP512 require square brackets around the values (for example,
[CL0-A-CL0-D]). Range arguments for the XP128/XP1024/XP10000/XP12000 should be specified
without square brackets (for example, 0A-0D).
Multiple values
For the XP48/XP512, when specifying multiple values, both ranges (for example, [CL1-A-CL1-D]) and sets
of values (for example, 0A,0B) are supported. Individual values are separated by “,” and a range by
square brackets and “-”.
For the XP128/XP1024/XP10000/XP12000, multiple values can be specified as a range (for example,
1A-1D) or a set of values (for example, 0A:0D). Individual values are separated by “:” and a range by “-”.
Port names
For the XP48/XP512, ports are specified as CL1-A or CL2-A, etc. (for example, the range [CL1-A-CL1-D]).
For the XP128/XP1024/XP10000/XP12000, you specify ports as 1A, 2A, etc. (for example, 1A-1D).