HP StorageWorks Command View XP Command Line Interface (CLI) reference guide (B9357-96161, January 2006)

198 Error messages
COUNT_FOR_VOLUME_INITIALIZE Invalid format. The format should be: list
count_For_Volume_Initialize [-pg <Parity Group>].
DEL_LUN_GRP_FORMAT Invalid format. The format should be: PortName,
LUNGrpNickname.
DEL_WWN_GRP_FORMAT Invalid format. The format should be: PortName,
WWNGrpNickname.
DELETE_CREATE_USER_<USER_NAME> Comma-separated parameters were entered. Check to make
only alphanumeric characters are used, and that no spaces
are entered.
DUPLICATE_ENTRY The entry already exists.
ERROR_MESSAGE Insufficient number of arguments.
EXECUTE_FORMAT Invalid format. The format should be: execute <filename>.
FAILURE The operation has failed.
FIBRE_FORMAT Invalid format. The format should be: PortName,
FibreAddr/FibreTopology.
HELP_INVALID_FORMAT Invalid format. The format should be either help OR help
<operation> OR help <operation> <module>.
HOSTMODE_FORMAT Invalid format. The format should be: PortName,
HostModeNumber.
HOSTMODE_NUMBER Invalid value. The host mode number is out of range.
INVALID_COMMAND_NOT_OPENV This command is supported only for the OPEN-V emulation
type.
INVALID_COMMAND_OPENV Please use the make volumes command for the OPEN-V
emulation type.
INSTALL_CV_FORMAT Invalid format. The format should be: install CV pgNumber,
cu1, ldev1, emulationType1,
ldevSize1[;cu2,ldev2,emulationType2,ldevSize2]...
INVALID_CMD The command is invalid.
INVALID_CMD_VALUE Invalid value. The command device value should be either
SET or RELEASE.
INVALID_CU_RANGE The CU value is out of range.
INVALID_CU_TYPE Invalid value. Should be a hex string.
INVALID_CU_VALUE Invalid value. The value is out of range.
INVALID_DATA Data is invalid.
INVALID_FIBRE_TYPE Invalid Fibre Addr/Topology.
INVALID_FORMAT Invalid record format. The record format should be operation
type and a space followed by fields.
INVALID_GROUP_NAME An invalid group name was entered. Check the name of the
group and try again.
INVALID_HOSTMODE_TYPE The program expected an integer value, but found a hex
string.
INVALID_LDEV_RANGE The LDEV value is out of range.
INVALID_LDEV_SEQUENCE Invalid LDEV value. The LDEV values must be in ascending
order.
Table 3 Error messages (continued)
Error message Problem/resolution