HP StorageWorks Command View XP Command Line Interface (CLI) reference guide (B9357-96161, January 2006)

204 Error messages
1028 Your request of the combined number of LDEVs was over the specification of LUSE
(Up to 36). Or, when LUSE is released, there is some LDEV that is included in the
Expanded LU, and be not set.
1029 The size of CV that are combined to expanded LU, are different each other. Or, you
want to combine CV and Normal Volume mixed.
1030 The area that was set for DCR is overlap to another DCR area.
1031 The size of area that was set for DCR is larger than volume size.
1032 The size of area that was set for DCR is larger than Cache size.
1033 The whole volume directions of DCR were specified to be Mainframe system volume.
1034 The classification of the specification method of DCR setting position and volume is
not in agreement. (LBA number is specified to Mainframe system volume.) A cylinder
number/header number is specified to be Open system volumes.
1035 The setup of required Subsystem ID is not carried out according to CVS operation.
1036 A to which the size of CV is over the range which can be set up (smaller than the
minimum value and larger than maximum): The contents of specification are
corrected and a demand is published again.
1037 The capacity for creating CV does not remain in Base Volume.
1038 What cannot be intermingled in the emulation type of CV was specified.
1039 It was going to perform CVS operation to the volume to which LU path is set, or the
volume by which LU extension is carried out.
1040 CU number of Normal Volume differs from CU number of Base Volume.
1041 Appointed CU number and LDEV number overlap the thing of other volumes by CVS
operation.
1042 The volume specified as Normal Volume by CVS operation is not Normal Volume.
1043 The volume specified as Base Volume by CVS operation is not Base Volume. Or the
volume specified as CV is not CV.
1044 Two or more CVs exist in Base Volume specified by CV to Normal.
1045 Specified Subsystem ID overlaps the existing Subsystem ID.
1046 The setting number of DCR to 1LDEV is over 16.
1047 The obstacle occurred in CVS increase-and-decrease operation.
1048 There is no specified volume or there was a deletion demand to the volume by which
DCR specification is not carried out.
1049 CV by which CVS specification for decrease operation was carried out was the
volume of only Base Volume.
1050 The volumes those are connected to expanded LU, include Reserved volume.
1051 In CVS operation, an error is in emulation type specification.
1052 It was going to include WWN already contained in a group in other WWN groups.
1053 It was going to collect WWN to which different access permission is set into WWN
group.
Table 4 XP48/XP512 error codes (continued)
Error code Description