HP StorageWorks Command View XP Command Line Interface (CLI) reference guide (B9357-96161, January 2006)
Command View XP Command Line Interface (CLI) reference guide 205
1054 When specifying Install CV at the time of Normal to CV operation, CU number and
LDEV number of Base Volume were not the same as CU number and LDEV number
which were specified by CV.
1055 It was going to set up access permission to LUN contained in LUN group.
1056 It was going to set up access permission to WWN contained in WWN group.
1057 It was going to include LUN already contained in a group in other LUN groups.
1058 It was going to collect LUN to which different access permission is set into LUN
group.
1059 It was going to perform LUN Security operation to the port which is not a Fibre port.
1060 It was going to perform LUN Security operation to LUN without LU path.
1061 LUN Security function tended to perform LUN Security operation to the invalid port.
1062 An error is in the size specification which suited the emulation type and the
emulation type to specify, at the time of Install CV setup. (User specification capacity
is specified to Mainframe system volume.) The number of user specification cylinders
is specified to be Open system volume.
1063 It was going to register the same WWN number as what is already registered.
1064 It was going to register the same WWN as what is already registered.
1065 It was going to register the same WWN nickname as what is already registered, or
WWN group nickname. (WWN nickname and WWN group nickname must not
overlap mutually.)
1066 WWN number not registered was specified (at the time of deletion or change).
1067 It was going to register the same WWN group number as what is already
registered.
1068 WWN group number not registered was specified (at the time of deletion or
change).
1069 It was going to register the same LUN group number as what is already registered.
1070 LUN group number not registered was specified (at the time of deletion or change).
1071 It was going to set up the functional switch to the port where WWN is not registered.
(When setting a functional switch as the port where WWN is not registered, you
have to register WWN simultaneously with a setup of a functional switch.) Or the
same setting demand as the contents set up now was published to the same port.
1072 It was going to register the same LUN group nickname as what is already registered.
1073 It was going to set up SubSystem ID without CVS operation.
1074 CU specified at the time of CVS operation (Install CV) cannot be set up.
1075 It was intermingled in one composition information setting demand, and CVS
operation (Normal to CV, CV to Normal, Install CV, Deinstall CV) was specified to
be it.
1076 It was going to create Reserve volume for Auto LUN to the volume which is the pair of
HODM/Hitachi TrueCopy - S/390/HP Continuous Access XP/Hitachi
ShadowImage - S/390/HP Business Copy XP.
1077 It was going to create Reserve volume for Auto LUN to the volume which is Reserve of
Hitachi ShadowImage - S/390/HP Business Copy XP.
Table 4 XP48/XP512 error codes (continued)
Error code Description