HP StorageWorks Command View XP Command Line Interface (CLI) reference guide (B9357-96161, January 2006)

Command View XP Command Line Interface (CLI) reference guide 217
31004 Failed to remove the path. The specified path is the last path of
TrueCopy/ShadowImage volume. Please Correct the contents of LU path setting, and
request the setting of the configuration information again.
31006 The emulation type of the LDEV to be combined as a part of LUSE is not an open
volume. Please check the setting.
31007 You are tying to set the LUSE including already expanded LU. Please check the
setting.
31008 The volume to be combined as a LUSE extends over CUs. In LUSE, all LDEVs should
belong to same CU number. Please check the setting.
31009 LU path is set to the volume to be combined as a LUSE. Please check the setting.
31010 The emulation types of the volumes to be combined as an expanded LUSE are not
the same. If you want to set the LUSE, you should select LDEVs of same emulation,
same capacity, and same volume attribute (either all should be Normal Volume or all
should be Custom Volume).
31012 LU path is set to the expanded LUSE to be released. Please release the path of the
target volume first, and then disperse the LUSE.
31015 The port specified as the element of the configuration change does not exist.
Unmounted port or mainframe port might be specified. Please check the port
specified.
31017 Invalid LUN. Please check the setting.
31018 The specified volume does not exist. Unmounted volume or mainframe volume might
be specified. Please check the port specified.
31019 Invalid host mode. Please check the setting.
31021 Invalid Fibre topology information. Please check the setting.
31022 The specified LU path does not exist. Please check the setting.
31024 The specified value of the command device setting is invalid. Please check the
setting.
31025 The number of volumes that can be combined as an expanded LU is exceeded.
(MAX.36). Please check the setting.
31026 The capacities of the volumes to be combined as an expanded LU are not the same.
Or, you are trying to mix Customized Volume and the normal volume (Native
Volume). If you set the expanded LU, set the same emulation, the volume of the same
capacity, and the same volume attribute (Native Volume or Customized Volume:
cannot be mixed).
31028 The extent set to Cache LUN exceeds the value which can be set in the target volume.
Since the Cache LUN extent which can be set by the volume is variable, check the
emulation type of the target volume. For details, call the HP Product Support.
31030 Entire volume instructions of Cache LUN needs to be specified. Please specify START
and END LBAs.
31031 The method of specifying the Cache LUN setting position and the volume type do not
match. Please specify the cylinder number/header number for mainframe volumes.
For open volumes, specify the LBA numbers.
31032 SSID is not set for the VSC operation. Please contact the HP Product Support.
Table 5 XP128/XP1024/XP10000/XP12000 error codes (continued)
Error code Description