31071 The CU specified during the CVS operation (Install CV) cannot be set. Correct the
specified contents.
31072 VSC operations (Initialize, Install CV, Delete LDEV) are specified in a single request
for the configuration information setting. This combination of settings is not allowed.
31098 The VSC operation is requested for the unmounted volume. Please check the settings.
31099 The volume(s) you tried to delete is/contains the last volume in the Parity Group. Last
Normal Volume cannot be deleted in a Parity Group.
31100 The parity group is not mounted in the VSC operation. Please check the settings.
31101 SSID not being set in the VSC operation. Please report to the HP Product Support.
31102 The number of the LDEV IDs which can be set in the VSC operation is exceeded.
(MAX.CU:0-31/LDEV:0-255). Note that the LDEV ID (Upper limit of CU) which can
be used is determined with the SM capacity. For details, call the support center.
31105 When changing the command device configuration, you cannot set the following
items. 1) Reserve volume for Auto LUN, 2) On-Demand volume, 3) Volume other than
OPEN volume (including unmounted volume) Please check the volume where the
command device is set.
31108 Nickname is not specified when the change of the LUN Security configuration is
requested. Please specify the nickname and perform the configuration change
request.
31110 The LDEV tried to be created in the VSC operation is being used as the HPAV
function. Change the specified volume ID, or cancel the HPAV settings.
31113 The value is not specified in WWN registration. Or, 0 is set to the value for WWN.
Please set the value for WWN and perform the configuration change request again.
31120 The setting of the command device security is requested, but the setting of the
command device for the target volume is not performed. When setting the command
device security, set the command device in advance or concurrently.
31121 The methods of setting the command device/command device security are wrong.
The following cannot be set for the same volume. 1) Setting command device +
Releasing command device security, 2) Releasing command device security + Setting
command device security. Correct the specified contents.
31122 In WWN registration, the host group where the WWN is registered does not exist.
Correct the specified contents.
31123 Command Device cannot be set for an expanded volume.
31124 Though CHA high-speed mode is specified, it is specified to the unmounted CHA.
Please check the channel package.
31125 Though the channel speed is requested to change, Fiber PCB is the unsupported
version. Please check the channel package.
31126 For WWN related configuration change requests in LUN Security operations, the
number of WWNs that can be registered (max. 255) per port is exceeded. Please
check the settings.
31127 Invalid character is used when HOST GROUP and WWN are registered. Please
change the name and try the configuration change request.
31128 For host group related configuration change request (add/delete/change), the
maximum number that can be set for a port is already reached. (range : 0-127)