HP StorageWorks XP24000 Remote Web Console Error Codes, v01 (AE131-96004, June 2007)

Part
Code
Error
Number
Error Message
Recommended Action
Severity
Level
Failure
Level
8105 1198
Since a path is dened to
an
external LU, you can not
set
high-speed mode.
Please correct the settings,
then
retry.
E
6
8105 1201
The selection of High Speed
mode/MIX mode is invalid.
The specied port cannot
be changed to High Speed
mode/MIX mode.
Change the parameter to a
path where the High Speed
mode/MIX mode can be
set, then retry the operation.
E 5
8105 1203
High Speed mode/MIX
mode
was spe
cied.
However, th
ere are
addresses t
owhich High
Speed mo de/ MIX mode
cannotbeset in theFibre
Addresses of the specied
ports.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
8105
1204
High Speed mode/MIX
mode
was specied.
However, there are
topologies to which
High Speed mode/MIX
mode
cannot be set in the
topologies of the specied
ports.
The Conguration
information has been
already changed.
Please check the settings
and request the setting of the
conguration information
again.
E
6
8105 1350
Add path to the initiator
port failed.
The port you are trying to
set
is for Fibre Continuous
Access. You must change
the
attribute when addi ng
apath. Attribute(TarGet or
RCU TarGet)
E
2
8105 1351
The high-speed or
initiator/external mix
mode
cannot be set to the
specied port because of
the
attribute of the port.
Can
not
set to high-speed
mod
e
because the
por
tattributesare
mi
xed, or cannot set to
in
ternal/external mix mode
be
cause the combination of
p
ortattributesisdifferent.
C
heck the port attributes,
t
hen
retry the operation.
E
6
8105 1352
Logical paths remain on
the
Fibre-MCU port. This
operation may cause a fatal
damage to the logical paths.
Please stop this operation.
If
you want to continue this
operation, please remove
the
logical paths from the
MCU
port rst.
Since the por t you are trying
to set
is for Fibre Continuous
Access, you must delete the
logical pa th, then retry the
port setting.
E
2
8105 1353
S-VOLs remain on the
Fibre-RCU port. This
operation may cause a
fatal damage to S -VOLs.
Please stop this operation.
If
you want to continue this
operation, please remove
the S-VOLsfromthe RCU
port rst.
Since the por t you are trying
to set
is for Fibre Continuous
Access, you must delete the
S-VOL logical path which is
set
to RCU Target, then retry
the
port setting.
E
2
344
HP
StorageWorks XP Remote Web Console for Storage System Messages and Error Codes