HP StorageWorks Fabric OS 5.x Fabric Watch Administrator Guide (AA-RVJ0B-TE, September 2005)

44 Configuring Fabric Watch
Table 15 describes the 18 customization options displayed at the end of the Advanced Configuration
menu.
Table 15 Advanced configuration options
Option Effect Input information
change behavior type Changes the behavior type of
a single element to either
Triggered or Continuous. The
change is volatile because this
option is not saved to flash
memory. Every time the switch
is rebooted, this option is
reset.
The element index and the
required behavior type
change behavior interval Changes the behavior interval
for a single element. The
change is volatile because this
option is not saved to flash
memory. Every time the switch
is rebooted, this option is
reset.
The element index and the
required behavior interval, in
seconds
change threshold
boundary level
Changes between the factory
default and custom threshold
information.
The required threshold column
change custom unit Changes the measurement
unit assigned to the monitored
data values, but only affects
the custom column.
The required measurement unit,
as a string
change custom time base Changes the time base for the
area, but only affects the
custom column.
The required time base
change custom low Changes the low setting for
the threshold, but only affects
the custom column.
The required low threshold, in the
units defined by the area
change custom high Changes the high setting for
the threshold, but only affects
the custom column.
The required high threshold, in
the units defined by the area
change custom buffer Changes the buffer size for the
threshold, but only affects the
custom column.
The required buffer size, in the
units defined by the area
apply threshold boundary
changes
Confirms the changes made to
the threshold information. This
must be done to retain the
changes made.
None
cancel threshold
boundary changes
Returns the boundary
information to the last
confirmed state.
None
change threshold alarm
level
Changes between the factory
default and custom event
settings for the area.
The required event setting column