HP StorageWorks Fabric OS 5.x Fabric Watch Administrator Guide (AA-RVJ0B-TE, September 2005)

Fabric OS 5.x Fabric Watch administrator guide 55
In this example, 83.1 is numeric identifier for the element referenced as resFlash000.
7. Traverse the fields beneath swFwClassAreaTable and swFwThresholdTable, appending the numeric
identifier from the previous step to each field before performing a get or write operation. For example,
to get and modify information specific to the resFlash000 element, select one of the fields and append
“83.1” in the Object ID field on the right side of the screen.
To modify information, you must define a write community. To modify an entry:
a. Select a field.
b. Append the numeric identifier to the Object ID.
c. Enter the new value into the Set Value field.
d. Select Set from the Operations menu.