HP StorageWorks Fabric OS 5.x Fabric Watch Administrator Guide (AA-RVJ0B-TE, September 2005)

Fabric OS 5.x Fabric Watch administrator guide 59
Power Supply Monitors power
supply condition
Unit: 1/0
(OK/FAULTY)
Time Base: none
The default threshold
settings for all
platforms are:
Low: 1
High: 0
Buffer:0
Changed: 0
Below: 3
Above: 3
In-Between: 0
Informative
Out_of_range
In_range
Informative
Temperature Monitors switch
temperature in
Celsius
Unit: degrees C
Time Base: none
HP StorageWorks
SAN Switch 2/8V,
2/16V, 2/16N
Low: 0
High: 64
Buffer: 10
HP StorageWorks
SAN Switch 2/32
Low: 10
High: 67
Buffer: 10
HP StorageWorks
SAN Switch 4/32
4100
Low:0
High: 60
Buffer: 10
HP StorageWorks
Core Switch 2/64
Low: 10
High: 75
Buffer: 10
HP StorageWorks
SAN Director 2/128
Low: 0
High: 75
Buffer: 10
Changed: 0
Below: 3
Above: 3
In-Between: 3
Informative
Out_of_range
Out_of_range
In_range
Table 17 Environment class threshold defaults (continued)
Area Description Default threshold
settings
Default alarm
settings
Threshold
state