HP StorageWorks Fabric OS 5.x Fabric Watch Administrator Guide (AA-RVJ0B-TE, September 2005)

Fabric OS 5.x Fabric Watch administrator guide 61
Performance monitor class
Table 19 provides default settings for areas in the AL_PA Performance Monitor class.
NOTE: End-to-end and AL_PA CRC counters are not supported on the HP StorageWorks SAN Switch
4/32.
Table 20 provides default settings for areas in the Customer-Defined Performance Monitor class.
Zoning Changes Monitors changes
to currently
enabled zoning
configurations
Unit: zone change(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
SFP State
Changes
Monitors SFP state
changes
Unit: Change(s)
Time Base:
Low: 0
High: 0
Buffer: 0
Changed: 0
Exceeded: 0
Below: 0
Above: 0
In-between: 0
Informative
Informative
Informative
Informative
Informative
Table 18 Fabric Class threshold defaults (continued)
Area Description Default threshold
settings
Default alarm
settings
Threshold
state
Table 19 AL_PA performance monitor class threshold defaults
Area Description Default Threshold
Settings
Default Alarm
Settings
Threshold
State
AL_PA Invalid
CRCs
Monitors the
number of
arbitrated loop
physical address
CRC errors
Unit: error(s)
Time Base: minute
Low: 0
High: 60
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Table 20 Customer-Defined performance monitor class threshold defaults
Area Description Default threshold
settings
Default alarm
settings
Threshold
state
Customer-Defined
Filter
Monitors the
number of
frames that are
filtered out by
the port
Unit: frame(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative