HP StorageWorks Fabric OS 5.x Fabric Watch Administrator Guide (AA-RVJ0B-TE, September 2005)

Fabric OS 5.x Fabric Watch administrator guide 63
Table 23 provides default settings for areas in the E-Port class.
Primitive
Sequence
Protocol Error
Monitors the
number of
primitive
sequence errors
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Receive
Performance
Monitors receive
rate, by
percentage
Unit: percentage
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
State Changes Monitors state
changes
Unit: error(s)
Time Base: minute
Low:0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit
Performance
Monitors
transmission
rate, by
percentage
Unit: percentage
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Table 23 E-Port class threshold defaults
Area Description Default threshold
settings
Default alarm
settings
Threshold
state
Invalid CRC
Count
Monitors the
number of CRC
errors
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Invalid
Transmission
Word
Monitors the
number of invalid
words transmitted
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Link Failure
Count
Monitors the
number of link
failures
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Loss of Signal
Count
Monitors the
number of signal
loss errors
Unit: error(s)
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Table 22 Port Class threshold defaults (continued)
Area Description Default threshold
settings
Default alarm
settings
Threshold
state