HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)

Preparing the Host System
111HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
First, the Cambex adapter driver, V1.5.26.0, is installed. The name of the driver
fileset is PC1000.driver.obj
Solution Software Installation for AIX V88
----------------------------------------
Installing Cambex adapter driver for AIX 4.3.3/5.1/5.2...OK
Issuing bosboot command...OK
Next, entries to ODM database are added so that the OS supports both HSG60 and
HSG80 controller-based subsystems. Since this is a new installation, the
installation script looks for devices by running the cfgmgr command. The fileset
names for the ODM entries are
hsg60.rte and hsg80.rte respectively
Device Support Filesets
----------------------------------------
Installing HSG60 ODM entries...OK
Installing HSG80 ODM entries...OK
Issuing bosboot Command... OK
Searching for HSG80 Devices...OK
The HSG80 devices that are found by the script are listed below.
Note: This output assumes that there are already units defined on the HSG80
controllers for this server.
HSG80 Devices
---------------------------------------
hdisk3 Available 20-60-00-0,0 DEC HSG80 Command Console LUN
hdisk4 Available 20-60-00-0,1 DEC HSG80 RAID Array
hdisk5 Available 20-60-00-0,2 DEC HSG80 RAID Array
hdisk6 Available 20-60-00-0,3 DEC HSG80 RAID Array
hdisk7 Available 20-60-00-1,0 DEC HSG80 Command Console LUN
hdisk8 Available 20-60-00-1,1 DEC HSG80 RAID Array
hdisk9 Available 20-60-00-1,2 DEC HSG80 RAID Array
hdisk10 Available 20-60-00-1,3 DEC HSG80 RAID Array
---Press ENTER to Continue---