HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)

FC Configuration Procedures
145HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
Setting Up a Controller Pair
The following procedures describe how to set up a controller pair.
Powering Up and Establishing Communication
1. Connect the computer or terminal to the controller as shown in Figure 36. The
connection to the computer is through the COM1 or COM2 ports.
2. Turn on the computer or terminal.
3. Apply power to the storage subsystem.
4. Configure the computer or terminal as follows:
9600 baud
8 data bits
1 stop bit
—no parity
no flow control
5. Press Enter.
A copyright notice and the CLI prompt is displayed, indicating that you
established a local connection with the controller.
Cabling a Controller Pair
The cabling for a controller pair is shown in Figure 38.
Note: It is a good idea to plug only the controller cables into the switch or hub. The
host cables are plugged into the or hub as part of the configuration procedure
("Configuring a Controller Pair Using CLI", page 146).