HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)
FC Configuration Procedures
146 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
Figure 38 shows a controller pair with failover cabling showing one HBA per
server with HSG80 controller in transparent failover mode.
Figure 38: Controller pair failover cabling
Configuring a Controller Pair Using CLI
To configure a controller pair using CLI involves the following processes:
■ "Establishing a Connection to the System Controller", page 146
■ "Configuring Controller Settings", page 147
■ "Setting This Controller", page 148
■ "Setting Time and Verifying All Commands", page 149
■ "Plugging in the FC Cable and Verifying Connections", page 151
Establishing a Connection to the System Controller
1. Establish a serial data connection to RAID system Controller A from your
host.
2. From the CLI prompt, enter:
1 Controller A
2 Controller B
3 Host port 1
4 Host port 2
5 Cable from the switch to the host FC adapter
6 FC switch
CXO6887B
6
6
5
5
1
2
4
3