HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)

FC Configuration Procedures
147HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
SHOW THIS_CONTROLLER FULL The current configuration of your RAID
HSG80 controller is displayed.
Configuring Controller Settings
3. Check the configuration (parameter settings) of your controller against those
listed in Table 15.
Note: Setting the SCSI version to SCSI-3 does not make the controller fully compliant
with the SCSI-3 standards.
4. Change any controller parameter settings inconsistent with those in Table 15
by entering the appropriate command for that parameter, as described in the
next section.
Note: After completing all of the required parameter changes, you must restart the
controller for the new settings to take effect.
Ignore the Restart Controller messages until you have finished making all the required
configuration parameter changes.
Table 15: Correct controller parameter settings, AIX
HSG80 Parameter
Settings for:
Loop Fabric
Prompt HSG80> HSG80>
Node (WWN) nnnn-nnnn-nnnn-nnnn nnnn-nnnn-nnnn-nnnn
Command Console LUN Enabled Enabled
Port 1 Topology LOOP HARD FABRIC
Port 2 Topology LOOP HARD FABRIC
Port 1 ALPA D5 N/A
Port 2 ALPA D6 N/A
SCSI Version SCSI-2 or SCSI-3 SCSI-2 or SCSI-3
New Connection OS Type AIX_CAMBEX AIX_CAMBEX