HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)

Backing Up, Cloning, and Moving Data
187HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
The following is an example for identifying the RAID set units in a single host
configuration using testvg as a hypothetical volume group.
# lsvg -p testvg
testvg:
PV_NAMEPV STATETOTAL PPsFREE PPsFREE DISTRIBUTION
hdisk5active54222 00..00..00..00..22
hdisk6active54223 00..00..00..00..23
# lsdev -Cc disk
hdisk0 Available 10-60-00-8,0 16 Bit SCSI Disk Drive
hdisk1 Available 20-60-00-4,0 Other SCSI Disk Drive
hdisk2 Available 30-60-00-0,0 DEC HSG80 RAID Array
hdisk3 Available 30-60-00
-1,0 DEC HSG80 Command Console LUN
hdisk4 Available 30-60-00-0,1 DEC HSG80 RAID Array
hdisk5
Available 30-60-00-0,2 DEC HSG80 RAID Array
hdisk6
Available 30-60-00-1,1 DEC HSG80 RAID Array
hdisk7 Available 30-60-00-1,2 DEC HSG80 RAID Array
hdisk8 Available 30-60-00-1,3 DEC HSG80 RAID Array
hdisk9 Available 30-60-00-1,4 DEC HSG80 RAID Array
#
Note: The target hdisks from lsvg command are hdisk5 and hdisk6.
Note: The CCL (hdisk 3) is the same host adapter as hdisk 5 and hdisk6.
Note: The S value for hdisk6 is the same as the CCL. The L value for hdisk6 is 1
therefore the RAID set unit number is D001.