HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)

Backing Up, Cloning, and Moving Data
188 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
Note: Since the S value is not the same as the CCL and L value is 2, the RIAD set unit
number for hdisk5 is D102.
For dual host connection configuration, the S value for the hdisk location code is
zero. However, any hdisks, associated with the D0XX and D1XX series storage
system units, is distinguished by their host adapter associations. As a
consequence, the CCL, by its host designation, determines the series.
Refer to the following dual host example:
# lsdev -Cc disk
hdisk0 Available 10-60-00-8,0 16 Bit SCSI Disk Drive
hdisk1 Available 20-60-00-4,0 Other SCSI Disk Drive
hdisk2 Available 30-60-00-0,0 DEC HSG80 RAID Array
hdisk3 Available 40-60-00-0
,0 DEC HSG80 Command Console LUN
hdisk4 Available 30-60-00-0,1 DEC HSG80 RAID Array
hdisk5
Available 30-60-00-0,2 DEC HSG80 RAID Array
hdisk6
Available 40-60-00-0,1 DEC HSG80 RAID Array
hdisk7 Available 40-60-00-0,2 DEC HSG80 RAID Array
hdisk8 Available 40-60-00-0,3 DEC HSG80 RAID Array
hdisk9 Available 40-60-00-0,4 DEC HSG80 RAID Array
#
Note: The target hdisks from lsvg command are hdisk5 and hdisk6.
Note: The CCL (hdisk 3) is the same host adapter as hdisk6. The L value for hdisk6 is
1 therefor the RAID set unit number is D001.
Note: Since hdisk5 host adapter string does not match the CCL and the L value is 2,
the RAID set unit number for hdisk5 is D102.