HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide (AA-RV1HA-TE, March 2005)
Planning Storage Configurations
69HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
Examples - Model 2200 Storage Maps, PTL Addressing
The Model 2200 controller enclosure can be combined with the following:
■ Model 4214R disk enclosure—Ultra2 SCSI with 14 drive bays, single-bus
I/O module.
■ Model 4254 disk enclosure—Ultra2 SCSI with 14 drive bays, dual-bus I/O
module.
Note: The Model 4214R uses the same storage maps as the Model 4314R, and the
Model 4254 uses the same storage maps as the Model 4354R disk enclosures.
■ Model 4310R disk enclosure—Ultra3 SCSI with 10 drive bays, single-bus
I/O module. Table 4 shows the addresses for each device in a six-shelf,
single-bus configuration. A maximum of six Model 4310R disk enclosures
can be used with each Model 2200 controller enclosure.
Note: The storage map for the Model 4310R reflects the disk enclosure’s physical
location in the rack. Disk enclosures 6, 5, and 4 are stacked above the controller
enclosure, and disk enclosures 1, 2, and 3 are stacked below the controller enclosure.
■ Model 4350R disk enclosure—Ultra3 SCSI with 10 drive bays, single-bus
I/O module. Table 5 shows the addresses for each device in a three-shelf,
single-bus configuration. A maximum of three Model 4350R disk enclosures
can be used with each Model 2200 controller enclosure.
■ Model 4314R disk enclosure—Ultra3 SCSI with 14 drive bays, single-bus
I/O module. Table 6 shows the addresses for each device in a six-shelf,
single-bus configuration. A maximum of six Model 4314R disk enclosures
can be used with each Model 2200 controller enclosure.
Note: The storage map for the Model 4314R reflects the disk enclosure’s physical
location in the rack. Disk enclosures 6, 5, and 4 are stacked above the controller
enclosure, and disk enclosures 1, 2, and 3 are stacked below the controller enclosure.