Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 25
53-1001767-01
Chapter
2
AG System Messages
AG-1001
Message <timestamp>, [AG-1001], <sequence-number>,, ERROR, <system-name>, N_Port ID
virtualization (NPIV) is not supported by fabric port connected to port <port>.
Probable Cause N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which the Access
Gateway is connected.
Recommended
Action
On switches running Fabric OS 6.0 or earlier versions, run the portCfgNpivPort command to
enable NPIV capability on the port connected to the Access Gateway. Refer to the Fabric OS
Command Reference manual for more information on this command.
Some blades and ports in a switch may not support NPIV. NPIV functionality can not be
enabled on such ports and they will not respond to NPIV requests. Refer to the Access Gateway
Administrator Guide, Appendix B, for specific AG-compatibility requirements.
On non-Brocade switches, refer to the manufacturer's documentation to determine whether
the switch supports NPIV and how to enable NPIV on these types of switches.
Severity ERROR
AG-1002
Message <timestamp>, [AG-1002], <sequence-number>,, WARNING, <system-name>, Unable to
find alternate N_Port during failover for N_Port
<port>.
Probable Cause Indicates no other N_Port is configured or the fabric was unstable during failover.
Recommended
Action
Check whether or not an alternate N_Port is configured.
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity WARNING
AG-1003
Message <timestamp>, [AG-1003], <sequence-number>,, WARNING, <system-name>, Unable to
failover N_Port <port>. Failover across different fabrics is not supported.
Probable Cause Indicates that the failover does not get blocked between two fabrics, although it is not a supported
configuration.
Recommended
Action
Configure two or more N_Ports to connect to the same fabric; then execute the ag --failoverenable
command to enable failover on these N_Ports.