Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)
Table Of Contents
- Contents
- About This Document
- Introduction To System Messages
- RASLog Messages
- AG System Messages
- AN System Messages
- AUTH System Messages
- ANV System Messages
- BKSW System Messages
- BL System Messages
- BLL System Messages
- BLS System Messages
- BM System Messages
- C2 System Messages
- CDR System Messages
- CEE CONFIG System Messages
- CER System Messages
- CHASSIS System Messages
- CNM System Messages
- CONF System Messages
- CTAP System Messages
- CVLC System Messages
- CVLM System Messages
- DAUTH System Messages
- EM System Messages
- ESS System Messages
- ESWCH System Messages
- EVMD System Messages
- FABR System Messages
- FABS System Messages
- FBC System Messages
- FCMC System Messages
- FCIP System Messages
- FCOE System Messages
- FCPD System Messages
- FCPH System Messages
- FCR System Messages
- FICON System Messages
- FICU System Messages
- FKLB System Messages
- FLOD System Messages
- FSPF System Messages
- FSS System Messages
- FSSM System Messages
- FW System Messages
- HAM System Messages
- HAMK System Messages
- HIL System Messages
- HLO System Messages
- HMON System Messages
- HSL System Messages
- HTTP System Messages
- IBD System Messages
- IBPD System Messages
- ICPD System Messages
- IPAD System Messages
- IPS System Messages
- ISCS System Messages
- ISNS System Messages
- KAC System Messages
- KSWD System Messages
- KTRC System Messages
- L2SYS System Messages
- LACP System Messages
- LANCE System Messages
- LFM System Messages
- LOG System Messages
- LSDB System Messages
- MFIC System Messages
- MPTH System Messages
- MQ System Messages
- MS System Messages
- MSTP System Messages
- NBFS System Messages
- NS System Messages
- NSM System Messages
- ONM System Messages
- PDM System Messages
- PDTR System Messages
- PLAT System Messages
- PMGR System Messages
- PORT System Messages
- PS System Messages
- PSWP System Messages
- RAS System Messages
- RCS System Messages
- RKD System Messages
- RMOND System Messages
- RPCD System Messages
- RTWR System Messages
- SAS System Messages
- SCN System Messages
- SEC System Messages
- SFLOW System Messages
- SNMP System Messages
- SPC System Messages
- SPM System Messages
- SS System Messages
- SSM System Messages
- SULB System Messages
- SWCH System Messages
- SYSC System Messages
- SYSM System Messages
- TAPE System Messages
- TRCE System Messages
- TRCK System Messages
- TS System Messages
- UCST System Messages
- UPTH System Messages
- WEBD System Messages
- XTUN System Messages
- ZEUS System Messages
- ZOLB System Messages
- ZONE System Messages
- Audit Log Messages
- AUDIT AG System Messages
- AUDIT AN System Messages
- AUDIT AUTH System Messages
- AUDIT BLS System Messages
- AUDIT CNM System Messages
- AUDIT CONF System Messages
- AUDIT CVLM System Messages
- AUDIT FCIP System Messages
- AUDIT FICU System Messages
- AUDIT FW System Messages
- AUDIT HTTP System Messages
- AUDIT IPAD System Messages
- AUDIT PORT System Messages
- AUDIT SEC System Messages
- AUDIT SNMP System Messages
- AUDIT SPM System Messages
- AUDIT SULB System Messages
- AUDIT SWCH System Messages
- AUDIT UCST System Messages
- AUDIT ZONE System Messages
30 Fabric OS Message Reference
53-1001767-01
AG-1019
2
Recommended
Action
Run the switchShow command to display the status of all ports in the system. Run the portCfgShow
command to display a list of ports currently configured as N_Ports. Ensure that the host is
connected to an F_port.
Severity ERROR
AG-1019
Message <timestamp>, [AG-1019], <sequence-number>,, WARNING, <system-name>, Unable to
failover N_Port <port>. No other N Port in port group:<pgid> is online.
Probable Cause Indicates that failover across port groups is not supported.
Recommended
Action
Check whether or not an alternate N_Port is configured in this port group.
Severity WARNING
AG-1020
Message <timestamp>, [AG-1020], <sequence-number>,, INFO, <system-name>, F_Ports to
N_Ports route/mapping has been changed.
Probable Cause Indicates that F_Port -to-N_Port mapping has been changed because the switch has come online
or some new N_Port/F_Port has come online.
Recommended
Action
Run the ag --mapshow command to display the updated F_Port-to-N_Port mapping.
Severity INFO
AG-1021
Message <timestamp>, [AG-1021], <sequence-number>,, WARNING, <system-name>, Unable to do
Preferred-Failover of F_Port <port>. Failover across different fabric is not
supported.
Probable Cause Indicates that the failover does not get blocked between two fabrics, although it is not a supported
configuration.
Recommended
Action
Change the preferred N_Port settings for this F_Port using the ag --prefset command.
Choose the preferred N_Port such that it is in the same fabric as the primary N_Port of this F_Port.
Use the ag --show command to check the fabric connectivity of N_Ports.
Severity WARNING