Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010)

Table Of Contents
Fabric OS Message Reference 31
53-1001767-01
AG-1022
2
AG-1022
Message <timestamp>, [AG-1022], <sequence-number>,, INFO, <system-name>, F_Port <fport>
is failed over to its preferred N_Port <nport>.
Probable Cause Indicates the specified F_Port is failing over to its preferred N_Port.
Recommended
Action
Run the ag --mapshow command to display the updated F_Port-to-N_Port mapping.
Severity INFO
AG-1023
Message <timestamp>, [AG-1023], <sequence-number>,, INFO, <system-name>, F_Port <fport>
mapped to offline N_Port <nport> is failed over to its preferred N_Port <pport>.
Probable Cause Indicates the specified N_Port has failed to come online. The F_Port mapped to this N_Port had its
preferred set and is online.
Recommended
Action
Run the ag --mapshow command to display updated F_Port -to -N_Port mapping.
Severity INFO
AG-1024
Message <timestamp>, [AG-1024], <sequence-number>,, INFO, <system-name>, F_Port <fport>
is failed back to its preferred N_Port <nport>.
Probable Cause Indicates the specified N_Port is failing back F_Ports, which are failed over to some other N_Port.
Recommended
Action
Run the ag --mapShow command to display the updated F_Port-to-N_Port mapping.
Severity INFO
AG-1025
Message <timestamp>, [AG-1025], <sequence-number>,, ERROR, <system-name>, Port group of
Slave N_Port <port> is different than its Master N_Port <m_port>.
Probable Cause Indicates that the port groups of the Master and Slave N_Ports are different while the Trunk Area
assigned to the attached F_Ports on the edge switch is the same.
Recommended
Action
Run the porttrunkarea --show command on the attached switch to display that the Trunk Area is
assigned to all ports in the system and run the porttrunkarea --enable command to reconfigure the
Trunk Area.
Severity ERROR